XCONSOLE COMMUNICATION PROTOCOL (April, 2008) Serial Settings for the master terminal: - 115200 baud - 8 data bits - 2 stop bits - No Parity
PROTOCOL STRING <01><READ/WRITE><SENDER><HEADER><VALUE>...<PROCESS><CHECKSUM><02> 1 1
<CHECKSUM> The Checksum is calculated from <01> to the character before the checksum, which should be <1F>. The formula used is:
EXAMPLES Example #1 – Mute: <01><57><7F><03><4D><55><54><30><08><20><09><21>&l
COMMAND AND CORRESPONDING VALUE TABLES AUDIO COMMAND ID Data Min Data Max Value Min Value Max Value Step Meter MTR0 Mute MUT0 0 1 OFF ON Mi
SPECIAL COMMAND ID COLUMN Data Level Increment #LVL 1 (<21>) #Steps of 0.25dB Level Decrement #LVL 0 (<20>) #Steps of 0.25dB SYS
ADVANCED SPECIFIC PROCEDURE Program Download 1. PC sends Download ON command (%PD0 with data = <21>) 2. PC starts sending each parameter (ju
Komentáře k této Příručce